2-Wire, 4-20 mA Loop Powered Torque Transmitters-39000X

Model #: MCRT® 39000X
Description:

Shaft style, two wire torque transmitter

Starting From: $8,720.00

Features

  • High Safety Margins  — Handle 4X Overloads
  • Ten Times the Noise Immunity
  • NIST Traceable, NVLAP* Accredited Dead Weight Calibration
  • Ferrite-free, Non-contact Signal Transformers
  • Switchable to 12 ±8 mA Mode
  • 10 to 28 Volt Power Input, Reverse Polarity Protected
  • Splashproof & Corrosion Resistant

 

Ranges

Model #
MCRT® 39001X(25-0)
Nm
2.82
Lbf-in
25
Model #
MCRT® 39001X(5-1)
Nm
5.65
Lbf-in
50
Model #
MCRT® 39001X(1-2)
Nm
11.3
Lbf-in
100
Model #
MCRT® 39002X(25-1)
Nm
28.2
Lbf-in
250
Model #
MCRT® 39002X(5-2)
Nm
56.5
Lbf-in
500
Model #
MCRT® 39003X(1-3)
Nm
113
Lbf-in
1000
Model #
MCRT® 39004X(25-2)
Nm
283
Lbf-in
2500
Model #
MCRT® 39004X(5-3)
Nm
565
Lbf-in
5000
Model #
MCRT® 39006X(1-4)
Nm
1130
Lbf-in
10000
Model #
MCRT® 39006X(2-4)
Nm
2260
Lbf-in
20000
Model #
MCRT® 39007X(25-3)
Nm
2820
Lbf-in
25000
Model #
MCRT® 39007X(5-4)
Nm
5650
Lbf-in
50000
Model #
MCRT® 39008X(1-5)
Nm
11300
Lbf-in
100000
Model #
MCRT® 39008X(25-4)
Nm
28200
Lbf-in
250000
Code N
Combined Error (% of Range)
≤±0.15
Temperature Effect Zero (% of Range/˚F/˚C)
≤±0.003/≤±0.0054
Temperature Effect Span (% of Reading/˚F/˚C)
≤±0.003/≤±0.0054
Code C
Combined Error (% of Range)
≤±0.07
Temperature Effect Zero (% of Range/˚F/˚C)
≤±0.002/≤±0.0036
Temperature Effect Span (% of Reading/˚F/˚C)
≤±0.002/≤±0.0036

Specs

Mechanical Overload:
400%
Analog Output:
CW = 4-20mA, CCW = 4-20mA, CW Bidirectional = 12±8 mA, CCW Bidirectional = 12±8 mA
Compensated Range ˚F/˚C:
+75 to +175/+24 to +79.4
Nominal Overange (% of Range):
125%
Usable Range ˚F/˚C:
-25 to +185/-32 to +85
Bandwidth (Bessel Response Filters):
dc to 200 Hz or, dc to 1 Hz, switch selected
Storage Range ˚F/˚C:
-65 to +225/-54 to +107
Power Supply:

10 to 28 Vdc, fused and reverse polarity protected

Available Options

  • Enhanced Performance (code C )
  • Foot mount (code F)
  • Magnetic Speed Pickup (code Z)
  • Explosion-Proof Speed Pickup (Code P)

When installed between a driver and its load, MCRT® 39000X torque transmitters measure bidirectional static (stall) and dynamic shaft torque and speed (an option). These devices use proprietary Himmelstein technology field-proven in four decades of use. A one piece stainless shaft carries bonded, foil strain gages. They measure torque, and in combination with element design, cancel bending and thrust loads. Rotary transformers connect the rotating gages to stationary, 4-20 mA transmitter circuitry. The transformers provide high quality non-contact signal coupling to the rotating gages. Rotary transformers don't wear or generate noise. They are immune to ambient noise, vibration, lubricants and other hostile environments.

MCRT devices provide the fastest, easiest, most ® dependable way to measure torque. The use of actual rather than inferred torque, mechanical power and energy makes possible otherwise unusable processes and machine control strategies. Control and verification of machine performance, efficiency, load, load sharing and detection of dangerous and wasteful conditions are valuable benefits. Examples are process and machine degradation, overload, load loss, and destructive torsionals.

MCRT 39000X’s incorporate new technology that ® harden them to the intense EMI generated by IGBTbased, adjustable speed drives. These devices have ten times the immunity of earlier 4-20 mA, loop powered torque transmitters. Transmitter Description When installed between a driver and its load, MCRT® 39000X torque transmitters measure bidirectional static (stall) and dynamic shaft torque and speed (an option). These devices use proprietary Himmelstein technology field-proven in four decades of use. A one piece stainless shaft carries bonded, foil strain gages. They measure torque, and in combination with element design, cancel bending and thrust loads. Rotary transformers connect the rotating gages to stationary, 4-20 mA transmitter circuitry. The transformers provide high quality non-contact signal coupling to the rotating gages. Rotary transformers don't wear or generate noise. They are immune to ambient noise, vibration, lubricants and other hostile environments. RFI shielding and the current output, provide high noise immunity. NIST traceable field adjustments are free of cable effects. There are no slip rings, brushes, radio transmitters and other noisy, limited-life elements. Unlike ferrite transformers, Himmelstein ferrite-free units aren’t susceptible to cracking and impact damage. Moreover, the robust, non-ferrite design suits these transmitters for diesel and other hostile environments.

Accessories

  • Model 706 Instrument - Torque Display Only
  • Model 726 Instrument - Torque and Speed Display
Cables (standard cable lengths are 20, 50 and 100 feet, replace XX in part number with desired cable length):
Torque to 706 or 726
224-6977V-XX
Speed to 726
224-5327V-XX