High Overload, Non-Contact, Flanged End, DC Operated Torque Transducers-59000V

Model #: MCRT® 59000V
Description:

High Overload, Non-Contact, Flanged End, DC Operated Torquemeters

Starting From: Please contact us. Product is obsolete.

Features

  • 10X Intrinsic Overload Capacity — No Mechanical Stops
  • 0.1% Accuracy NIST Traceable and Remote Calibration
  • Highest Torsional Stiffness Shaft End Units
  • Hardened To EMI From IGBT-based Adjustable Speed Drive

Ranges

Model #
MCRT® 59060V( 2-2)
Nm
22.6
Lbf-in
200
Model #
MCRT® 59060V( 4-2)
Nm
45.2
Lbf-in
400
Model #
MCRT® 59060V( 8-2)
Nm
90.4
Lbf-in
800
Model #
MCRT® 59061V( 2-3)
Nm
226
Lbf-in
2000
Model #
MCRT® 59061V(36-2)
Nm
407
Lbf-in
3600
Model #
MCRT® 59070V(48-2)
Nm
542
Lbf-in
4800
Model #
MCRT® 59070V(96-2)
Nm
1080
Lbf-in
9600
Model #
MCRT® 59070V(192-2)
Nm
2170
Lbf-in
19200
Model #
MCRT® 59080V(4-4)
Nm
45
Lbf-in
40000
Model #
MCRT® 59080V(75-3)
Nm
8470
Lbf-in
75000
Model #
MCRT® 59090V(15-4)
Nm
16900
Lbf-in
150000
Model #
MCRT® 59090V(3-5)
Nm
33900
Lbf-in
300000
Model #
MCRT® 59090V( 4-5)
Nm
45200
Lbf-in
400000
Model #
MCRT® 59091V( 6-5)
Nm
67800
Lbf-in
600000
Model #
MCRT® 59091V(735-3)
Nm
83000
Lbf-in
735000
Code N
Combined Error (% of Range)
±0.10
Temperature Effect Zero (% of Range/˚F/˚C)
≤±0.0025/≤±0.0045
Temperature Effect Span (% of Reading/˚F/˚C)
≤±0.0025/≤±0.0045

Specs

Mechanical Overload:
1000%
Analog Output:
CW = +5 Volts and CCW -5 Volts
Compensated Range ˚F/˚C:
+75 to +175/+23.9 to +79.4
Nominal Overange (% of Range):
150%
Usable Range ˚F/˚C:
-25 to +185/-32 to +85
Bandwidth (Bessel Response Filters):
High Frequency Output: DC to 500 Hz and Low Frequency Output: DC to 1 Hz
Storage Range ˚F/˚C:
-65 to +225/-54 to +107
Power Supply:

10.5 to 24 Volts dc

Available Options

  • Standard Pickup (Code A)
  • Speed and power output (Code Z)
  • 10 Volt Output (Code L)
  • 1,100 Hz Output (Code K)

Accessories

  • Model 703 Instrument - Torque Display Only
  • Model 723 Instrument - Torque and Speed Display
Cables (standard cable lengths are 20, 50 and 100 feet, replace XX in part number with desired cable length):
Torque to 703 or 723
224-7696-XX
Zero Speed to 723
224-5327V-XX
Standard Speed to 723
224-3683V-XX