REQUEST A QUOTE or ASK A QUESTION ABOUT THIS PRODUCT
Available Options
  • Zero Velocity Speed Pickup (Encoder - 512 ppr) - Code Z
  • Zero Velocity Speed Pick-up (Encoder - 512 ppr) with Line Driver - Code B

 

Low Capacity DC Operated Torque Transducers - 2X

Model #48000V

These low range models are available in capacities from 10 ozf-in to 400 ozf-in with overload ratings of 2X full scale. With integrated signal conditioning electronics, they have dual ±5 volt dc outputs for direct interface with PC, PLC controllers and data acquisition systems.

When installed between a driver and load, the sensor will measure static and dynamic shaft torque and speed (optional). A strain gaged titanium shaft senses torque and cancels bending and thrust. Robust, ferrite free rotary transformers connect the gages to noise immune carrier amplifiers. They don't generate noise or wear, are immune to magnetic fields, noise, vibration, lubricants and other hostile environments.

High stiffness to inertia ratios makes these sensors ideal for stepper motor and other dynamic applications. Maximum speed rating is 15,000 rpm, or 25,000 rpm with Option H. A dual track 512 PPR encoder is optional as is a line driver for its output(s).

General Specifications

Nonlinearity (% of full scale)

±0.1

Hysteresis (% of full scale)

±0.1

Nonrepeatability (% full scale)

±0.06

Accuracy (combined nonlinearity, hysteresis and non-repeatability, % of full scale)

±0.15

Rotational Effect on Zero (% of full scale)

±0.05

Remote Calibration Accuracy (% of full scale @ 75 deg F; traceable to NIST)

±0.05

Temperature Effects:

 

Zero (% of full scale/deg F.)

±0.003

Span (% of reading/deg F.)

±0.003

Compensated Range

+75 to +175 deg F

Minimum Useable Range

-25 to +185 deg F

Storage Range

-65 to +225 deg F

Outputs:

 

Clockwise Torque

+5 Volts

Counterclockwise Torque -5 Volts
Bandwidth:  
High Frequency Output dc to 500 Hz
Low Frequency Output dc to 1 Hz
Input Power 10.5 to 24 volts dc @ 85 mA, nominal