Himmelstein Load Cells are sealed, low profile sensors suitable for precision force and weight measurements. Measurement principle is strain gage and is compensated to eliminate temperature induced zero and span errors. Sensor design provides exceptional tolerance of extraneous loads.
Model Number |
Optional Base Part Number |
Range |
Overload Capacity |
Output |
| LBS |
LBS |
mV/V |
UNIVERSAL LOAD CELLS: |
| 2940(5-1) |
338 |
50 |
75 |
2 |
| 2940(1-2) |
338 |
100 |
150 |
2 |
| 2960(25-1) |
340 |
250 |
375 |
2 |
| 2960(5-2) |
340 |
500 |
750 |
2 |
| 2540(1-3) |
322 |
1,000 |
1,500 |
4 |
| 2540(2-3) |
322 |
2,000 |
3,000 |
4 |
| 2540(5-3) |
324 |
5,000 |
7,500 |
4 |
| 2540(1-4) |
324 |
10,000 |
15,000 |
4 |
| 2560(25-3) |
326 |
25,000 |
37,500 |
4 |
| 2560(5-4) |
326 |
50,000 |
75,000 |
4 |
| 2584(1-5) |
344 |
100,000 |
150,000 |
4 |
| 2600(2-5) |
330 |
200,000 |
300,000 |
4 |
COMPRESSION LOAD CELLS: |
| 2542(1-3) |
322 |
1,000 |
1,500 |
2 |
| 2542(2-3) |
322 |
2,000 |
3,000 |
2 |
| 2542(5-3) |
324 |
5,000 |
7,500 |
4 |
| 2542(1-4) |
324 |
10,000 |
15,000 |
4 |
| 2562(25-3) |
326 |
25,000 |
37,500 |
4 |
| 2562(5-4) |
326 |
50,000 |
75,000 |
4 |
| 2582(1-5) |
344 |
100,000 |
150,000 |
4 |
| 2602(2-5) |
330 |
200,000 |
300,000 |
4 |
Bridge Impedance |
350 ohms ±1% |
Zero Balance |
±1% of range |
Maximum Excitation Voltage (ac or dc) |
2500 Series |
20 volts |
2900 Series |
15 volts |
Nonlinearity |
0.05% of range |
Hysteresis |
< 5,000 lbf range |
0.02% of range |
5,000 lbf range and greater |
0.04% of range |
Non-repeatability |
0.02% of range |
Tension & Compression Symmetry |
0.1% of range |
Overload Capacity |
1.5 times range |
Temperature Effects |
Compensated Range (°F) |
+15 to +115 |
Operating Range (°F) |
-65 to +200 |
Zero Drift (% of range per °F) |
0.0008 |
Span Drift (% of reading per °F) |
0.0008 |
|
|