| Torque Range: lbf-in N-m |
| Overload Rating: lbf-in N-m |
| Shaft Stiffness: lbf-in/rad N-m/rad |
These strain gage based Horsepower/kW-h Meters measure and output shaft power, energy (option), torque and speed in analog and digital form. Digital computation of power and energy is errorless. They are available in ranges from 25 lbf-in to 2,000,000 lbf-in (power ranges from 5.95 to 38,100 hp) with a 4X overload capacity. Both shaft and flange style models are offered.
Null, scaling and units of measure are stored in non-volatile memory. There are no noisy pots or switches. Fifty-one common units of measure are supported without requiring recalibration. Eleven user selectable Bessel filters avoid delay distortion and overshoot errors. These models incorporate new technology that hardens them to EMI generated by IGBT based adjustable speed drives.
Included software interfaces Windows-based PC’s and displays and plots real time data. Use it to select 5V or 10V analog outputs, filters, scaling, units of measure and/or to control measurements.
|
Code N Performance |
Code C Performance |
Nonlinearity (end point, % of full scale) |
Power, Energy and Torque |
±0.1 |
±0.05 |
Speed |
±0.01 |
±0.01 |
Hysteresis (end point, % of full scale) |
Power, Energy and Torque |
±0.1 |
±0.05 |
Speed |
±0.01 |
±0.01 |
Nonrepeatability (% full scale) |
Power, Energy and Torque |
±0.05 |
±0.03 |
Speed |
±0.005 |
±0.005 |
Combined Accuracy (% of full scale) |
Power, Energy and Torque |
±0.13 |
±0.08 |
Speed |
±0.06 |
±0.06 |
Rotational Effect on Zero (% of full scale) |
±0.05 |
±0.03 |
Temperature Effects (Power, Energy and Torque) |
Zero (% of full scale/deg F.) |
±0.003 |
±0.0015 |
| Span (% of reading/deg F.) |
±0.003 |
±0.0015 |
| Compensated Range |
+75 to +175 deg F |
| Minimum Usable Range |
-25 to +185 deg F |
| Storage Range |
-65 to +225 deg F |
| Analog Outputs, Auto-Scaled |
| Power, Energy and Torque |
±10 or ±5 Volts dc, user selectable |
| Speed |
+10 or +5 Volts dc, user selectable |
| Nominal Overrange (% of full scale) |
50 |
| Signal Filter Cutoff |
0.1 to 200 Hz in eleven 1-2-5 steps, user selectable |
| System Resolution (% of full scale) |
0.02 (14 bits with 50% overrange) |
| RS232 Communications Port |
Outputs Power, Energy, Torque and Speed with units of measure. Inputs range selections, scaling, cal info and units of measure. |
| Supply Voltage |
11 to 24 volts dc @ 150 mA, nominal |
|
|